Model Number |
AMS-150L |
Power Saving Motion Detection Sensor Feature
- Wireless type : Totally different from common infrared sensor.(covers huge space)
- It automatically turns on and off the light by detecting movements within 20 square meter
- Depends on brightness setting, it may turns on and off the light even though there is human existence.
- By installing extra-sensor, it may expand detecting space.
- Usage : Toilet, hallway, lecture room, office, warehouse, factory where electric system control by detection is needed
- Effect
1)Saves energy 2)Efficiency(automatically turns on/off) 3)Safety(prevent from overheat of lights through careless use)

Precautions This manual has been made for users to use the product in its appropriate way, as well as prevent any damage to users properties and to maintain safety. Please read the instructions of this manual carefully prior to the product's installation.
- The product should be installed by an electrician or other qualified personnel.
- The product is made suitably for the light-on/off action of indoor lighting instruments.
(Please do not install it outdoors)
- Avoid medical equipment and wireless equipment in the installation of the product due terrors in operation by their wireless wave(RF)
- Applying impact or excessive force to the product causes a problem to its performance and function
- Do not touch the product with wet hands because of the possibility of getting and electric shock.
- The location at the upper end of a corner with command of a whole view is suitable for the installation of the product though it can be different depending on the sensing scope.
- A large obstacle or a source interrupting the product's RF wireless signal in the sensing scope may cause errors in its operation.
- If there is a continuously moving object within the sensing scope remove it from there or replicate the sensor to where no such moving object exists.
- Please contact the maker or the agency nearby of you have any inquiries concerning the product when a problem arises.
Start
1. Before you use this Green-Saver, you should aware of this manual. And you must pay attention to any other accident because of taking this saver apart discretionary.
2. Considerations prior to installation
- Location Selection
Select the location at which the power saving effect can be maximized with application of Sensing Scope
- Selection of sensor Location
Install the sensors at locations that are appropriate for sensing scopes and where people frequently visit.
- Selection of Power Load
Select the fluorescent lamps that are operate within the rated load of (AC220V/AMS-2000, 2,000W, AMS-300, 3,000W). If it sin necessary to exceed the rated load. You can extend the rated of 5KW with setting up the additional monolithic element SSR.
- Light-on Time set
Set time according to the special features of the lighting-on location. Time should be 5 minutes at minimum to avoid unnecessary lighting-on and lighting-off(Recommended). The timer of sensor can be adjusted at any time if a change of lighting-on time is necessary.
- How to wire
Wire reference to the map of wiring
## Precautions
- Black and white wires is used power source that operates Green Save.
- Two yellow wire is Switching-wire. It turns on when human motion sensed, and turns off when Time-set pass.
Notice : A circuit is out of use, if yellow ire is connected power source. Don't service free charge, because of mistake of wiring.
3. Accessories

4. How to Wire

5. Opening the cover
 |
1. Select installation spot and take out the screw at the down of the product. 2. Push the cover button and open the cover 3. To use the product, off the switch(3) * If there is damage, on the switch(3) so that it may be manually restart. |
6. Inner structure of a sensor
 |
1. Detection LED Real-time lighting on if a motion is sensed.(Use to check the sensing distance) 2. LUX sensor 3. Sensor module Microwave motion sensor 4. LED Switch(LED) Using LED or not, timer 1 or 10 minutes. 5. Timer setting switch(TIME) 6. Range control switch(SEN) Adjust sensing range maximum 15M 7. Brightness(of the surroundings) adjust switch(LUX) |
7. Time setting
 |
a. LED switch(On set for the first time) On the detection LED Real-time lighting-on when a motion is detected (Use to check the sensing-distance) OFF : LED not in use ON : LED use
#2 Switch that controls the time unit setting (Off set for the first time) OFF : Setting for time switch is 1min (If the time switch is 2, 2min is set) ON : Setting for time switch is 10min (If the time switch is 2, 20min is set)
b. SEN switch(lighting-off setting switch) Time setting switch works independently to set 3min off the LED(2) switch and on the SEN switch(1,2)(1+2=3) [Time is set by 16(hexadecimal) 1,2,3,4,] *Test mode : When LED(2) switch is off and time switch is 0. It turns light on for 5sec and turns off as a test mode. When LED(2) switch is on, it turns on for 10sec.
|
c. Dip switch use method

8. Sensing range setting
 |
a. SEN switch(sensing range adjustment) (15M set for the first time) Sensing range setting switch works independently, When 0 is set, minimum(3M) is set When 7 is set, maximum(15M) is set You can adjust the range as you want, *Range may be different depends on the space.
b. Sensing scope is a 80° horizontal angle, a 40° vertical angle with maximum distance of 15M(Adjustable 3M ~ 15M) Sensing the obstacle every where without the dead angle area in the room. Enhancing both the sensing cope and its sensitivity in a little bit of closed space. For instance, bathrooms, narrow and long corridors, and etc.
|

9. Brightness setting
 |
a LUX switch(brightness setting switch) (On is set for the first time) Brightness setting switch works independently when 0 is set, minimum brightness(under 10LUX) 1(100LUX), 2(200LUX), 3(300LUX), 4(400LUX), 5(500LUX), 6(600LUX), and 7 is set, maximum brightness(over 600LUX) and works with sensing movements.
|
b. Dip witch use method

Problem solution
|
|
Problem : It doesn't work when the power for sensor is on. Solution : 1)Cut off of power supply or low voltage supply. Check the power supplier and power connecting cable or the power supplied. 2)Sensor working Fuse disconnection. Supplied power problem or mis-work in sensor system. (Inquire us and repair request) |
|
|
Problem : While moving, lights are turned off. Solution : 1)Sensing scope is too narrow. By adjusting SEN switch, expand sensing scope. 2)Not in sensing direction. Adjust sensing direction. 3)Movements are small and low. Expand lighting-on time. 4)Larger space than maximum sensing scope. Move sensor or extra sensor installation is needed. |
|
|
Problem : lights don't turn on. Solution : 1)Brightness around sensor is lighter than the set LUX. Adjust LUX switch. 2)Output load FUSE disconnected. Overload of 3,000W might cause disconnection so load capacity adjustment is needed. solve the overload and change FUSE. |
|
|
Problem : light's don't turn off. Solution : 1)lighting-on time is too long. Adjust time switch 2)Within sensing scope continuous movement exist for instance, fans cotton, pets, etc. adjust sensor location or remove continuous movement. |
Environmental and technical capacity
|
|
|
Operation temperature/humidity
|
-5~55°C/10~90%RH -10~70°C/5~95%RH
|
|
Regular input voltage
|
220VAC
|
|
Input voltage range
|
AC 85V~265V(Free Voltage)
|
|
Power Frequency
|
50/60Hz
|
|
Consumption voltage
|
Below 1W
|
|
Load Capacity
|
AMS-150L/200W
|
|
Sensing range
|
130~150°horizontal / 40°vertical angle
|
|
Sensing scope
|
Regularly 15M(more than 20 in corridor from space)
|
|
Dimensions
|
73(W) x 100(H) x 74(D)mm
|
|
Operation Time
|
5sec, 10sec, 1~90Minutes
|
|
Contents
|
AMS-150L Manual, Conntection cable, Fixing screw, Fixing blacket.
|
|
Product certification
|
Ministry of Industries and resources competitive product certification, Ministry of medium and small Business quality certification, ENC certification |
|
Awards
|
Patent technology award, Innovative technology competitive comperition award, 2nd prize of patent technology competition, Engineering award. |

|